Electra One MK2 — integration guide
Companion to electra-one.json. Loaded automatically by osc-bridge and served
via /bridge/docs. Targets both human integrators and LLM-driven clients.
OSC prefix for this device: /electra1
Device: Electra One MK2, firmware 4.x.
Hardware-verified against Electra One MK2 firmware 4.1.4 (serial EO2-4312746f, hw revision 3.0) on 2026-04-14: upload round-trip, route registration, pot mapping, SysEx ACK/NACK, introspection endpoints, and rendering of all control types (fader, list, pad, adsr, adr, dx7envelope) all validated end-to-end.
1. Quick start — what Kanopi needs to do
- Upload a preset →
/electra1/preset/upload <json_string>- Reconfigures the device and rebuilds the bridge's semantic CC routes.
- Single SysEx, no arm step. ~200 ms until the device is ready.
- Listen for semantic events →
/electra1/page<N>/<control_name>(float 0..1) - Drive controls back → send OSC on the same semantic addresses.
- Query state whenever → see §4 introspection endpoints.
- Mutate a live preset without reuploading →
/electra1/control/update(name / color / visible) or/electra1/lua(arbitrary Lua, once a script is attached to the slot). See §7.
2. Preset JSON format (what you must generate)
Top-level:
{
"version": 2,
"name": "MyPreset",
"pages": [ { "id": 1, "name": "…" }, … up to 6 ],
"devices": [ { "id": 1, "name": "…", "port": 1, "channel": 1 }, … ],
"groups": [ { "pageId": 1, "name": "…", "color": "white", "bounds": [x,y,w,h] }, … ],
"controls": [
{
"id": 1, "pageId": 1, "name": "Cutoff", "type": "fader",
"bounds": [x, y, w, h], "color": "orange",
"values": [
{ "id": "value", "min": 0, "max": 127, "defaultValue": 64,
"message": { "type": "cc7", "parameterNumber": 74, "deviceId": 1 }
}
]
}
]
}
Control types (all hardware-validated)
fader, vfader, list, pad, adsr, adr, dx7envelope, custom.
faderis the default vertical bar.listrequires anoverlaysentry (id-referenced fromvalues[].overlayId) mapping numeric ranges to string labels (e.g.{0→"SQR", 43→"TRI", 85→"SAW"}).padis a button; set"mode": "toggle"and themessageblock must includeonValue/offValue.adsr/adr/dx7envelopeare multi-point visual envelopes. See § 6 for the envelope-segment-editing gesture — it's not what you'd guess.customis a Lua-painted tile (the canvas under yoursetPaintCallback). Required for any widget whose visual is implemented in Lua rather than as one of the firmware's built-in controls (step sequencers, custom meters, note-list editors, etc.). Thevalues[]array still drives the parameter wiring, but the paint surface is entirely your code's responsibility.
Custom-tile pot dispatch quirk (firmware 4.1.4): when type:"custom", the
firmware dispatches pot events to the tile from one pot only, regardless of
how many entries the control's inputs[] array declares. Multi-pot custom
controls is forum thread #4172
— acknowledged as a requested feature, not yet shipped. Design custom widgets
around one-pot interaction (mode toggles, double-click variants, touchscreen
gestures) rather than multiple physical encoders per tile.
Required field: inputs
Every control must declare "inputs": [{"potId": N, "valueId": "value"}].
Hardware-verified: without this, the firmware falls back to a near-random pot
assignment (observed: a single pot driving multiple on-screen controls in lock-step).
potId is 1..12 matching KNOB1 (top-left) .. KNOB12 (bottom-right).
Colours must be hex 6-char (no #)
Example: "F49500" (orange), "529DEC" (blue), "03A598" (teal), "C44795"
(pink), "FFD232" (yellow), "F45C51" (red), "FFFFFF" (white).
Named palette values like "orange" or "blue" are silently rejected —
the device accepts the upload (ACK) but fails to render properly and may
freeze.
Message types
cc7, cc14, nrpn, program, sysex. Only cc7 currently gets a
semantic OSC route in the bridge — the others render and emit MIDI but fall
back to /electra1/cc/{num} generic routing. Extending this is a one-line
change in the driver's upload script.
Colors (palette)
white, red, orange, blue, green, pink, purple, yellow.
Grid and control sets (MK2 hardware-verified)
Each page has up to 3 control sets, switched by the 3 physical buttons on the left side of the device (labeled SECTION 1 / 2 / 3) or by tapping a control on the touchscreen (taps auto-activate that control's set).
Each control set can contain up to 12 controls, one per physical pot
KNOB1..KNOB12. controlSetId on a control (1, 2, or 3) places it in a specific
set. Only one set is visually active at a time.
X/Y bounds are in pixel coordinates on the 1024×565 drawing area (the
physical panel is 1024×575 but the firmware's slot-bounds math caps at 565 —
verified against app.electra.one's displayHeight constant at offset
~129500 in 0c61af0.js). Typical column layout for 6 columns:
x = 14, 181, 348, 515, 682, 849 with width 158. Typical two-row layout:
y = 40 (top) and y = 320 (bottom). Full slot-bounds math for any slotId
is in §11 (Layout math reference).
Upload targets the currently-selected slot
/preset/upload writes to whatever slot was last selected on the device
(either via a /preset/switch beforehand, or via the UI). Always pair the
upload with /preset/arm_upload <bank> <slot> first if you need to target
a specific slot — otherwise you will overwrite whatever preset happens to be
loaded, which can destroy user work.
3. Semantic address derivation (for reference — prefer introspection)
The bridge normalizes control names to addresses like:
/electra1/page<N>/<slug>
<N>= index of the page inpages[](1-based), not the pageid.<slug>=name:lower():gsub('[^%w]+', '_'):gsub('^_+',''):gsub('_+$','')"Filter Cutoff"→filter_cutoff"Osc 1 & FX"→osc_1_fx
Recommended: don't derive these yourself. Call /electra1/routes/list
after every upload and use the returned addresses verbatim.
Values on the wire are always normalized float 0..1, regardless of the
preset's declared min/max. Clients that need the scaled value compute
min + norm * (max - min) themselves.
Channel in the route = device.channel - 1 (Electra is 1-indexed, MIDI 0-indexed).
4. Introspection endpoints (discovery)
| Send | Receive |
|---|---|
/electra1/routes/list |
N× /electra1/routes/entry <addr> <ch> <cc> <page> <min> <max> + /electra1/routes/done |
/electra1/preset/current |
/electra1/preset/current <name> |
/electra1/page/current |
/electra1/page/current <n> (or -1 if unset) |
/bridge/status |
/bridge/status/device <slug> <status> per device |
/bridge/docs |
/bridge/docs/device <slug> <markdown> (this file) |
After an upload, always poll /routes/list to learn the authoritative
address table — the slugification rule is a current implementation detail
that may evolve.
5. Spontaneous events (subscribe by default)
The bridge forwards device-initiated events as they arrive:
| OSC address | Meaning |
|---|---|
/electra1/ack <tx_lsb> <tx_msb> |
SysEx command acknowledged |
/electra1/nack <tx_lsb> <tx_msb> |
SysEx command rejected |
/electra1/page/switched <page> |
User changed page on the device. Bridge auto-updates current_page. |
/electra1/preset/switched <bank> <slot> |
Loaded preset slot changed |
/electra1/preset_bank/switched <bank> |
Bank changed |
/electra1/pot/touch <pot_id> <control_lsb> <control_msb> <touched> |
Touch-sensitive pot began/ended contact |
/electra1/preset_list/changed |
Presets list modified on device (7E 05) |
/electra1/snapshot_list/changed |
Snapshot library modified (7E 03) |
/electra1/snapshot_bank/switched <bank> |
User changed snapshot bank (7E 04) |
/electra1/control_set/switched <set> |
User pressed SECTION button or tapped a tile of another set (7E 07) |
/electra1/capture_list/changed |
MIDI capture library modified (7E 31) |
/electra1/usb_host/changed |
USB Host port: a controller (re)connected on the device's USB-Host jack |
/electra1/log <text> |
print() output and runtime Lua errors from device (7F 00) — not yet emitted by osc-bridge; the SysEx arrives but the driver doesn't surface it as OSC. Easy add: one entry in replies[] |
6. Workflow recipes
Upload to a specific bank/slot
/electra1/preset/arm_upload <bank> <slot> # "Set Preset Slot" (misnamed for history)
/electra1/preset/upload <json> # writes JSON into the selected slot
/electra1/preset/switch <bank> <slot> # optional: activate it for display
Wait for /electra1/ack before assuming success.
Editing envelope segments (MK2 UI gesture)
adsr / adr / dx7envelope controls show one pot binding at a time on the
hardware, even when inputs declares multiple {potId, valueId} entries. To
cycle through segments:
- Touch-and-hold the envelope's pot, then tap the envelope on the touchscreen. The pot's assignment cycles to the next value (Attack → Decay → Sustain → Release → Attack…).
- Or long-press the envelope control on screen to open a detail window where all values are simultaneously editable.
If your client wants independent pot control over each segment, use separate
fader controls per segment instead of a visual envelope widget.
Switch to an existing stored preset
/electra1/preset/switch <bank> <slot>
Send raw SysEx (power users)
/electra1/raw/syx "F0 00 21 45 … F7"
7. Live mutation — changing a preset without reuploading
Two SysEx paths let a client mutate an already-loaded preset in-place. Both are hardware-verified on MK2 firmware 4.1.4 (2026-04-18).
7.1 /control/update — declarative field mutation (opcode 0x14 0x07)
Signature: /electra1/control/update <control_id:u14> <json_patch:string>
The JSON patch is a subset of the control's fields; only the listed keys change.
Reverse-engineered from jorisroling/bitwig-electra-one (Electra One.control.js).
| Patch field | Effect | Status |
|---|---|---|
name |
Renames the on-screen label | ✅ works |
color (hex 6-char string, no #) |
Changes the control's color | ✅ works |
visible (bool) |
Shows / hides the control | ✅ works |
bounds ([x,y,w,h]) |
Intended to move/resize | ⚠️ ACK but silently ignored by firmware |
values[].defaultValue |
Intended to change default | ⚠️ ACK but silently ignored |
invalid control_id |
— | ⚠️ firmware ACKs instead of NACKing (robustness gap) |
| malformed JSON body | — | ✅ correctly NACKed |
Mutations persist across preset switch-away-and-back; they are stored slot-side.
7.2 /lua + /lua_script/upload — imperative runtime mutation
/electra1/lua <lua_source:string> (opcode 0x08 0x0D) executes Lua in the
context of the currently-loaded preset's Lua runtime.
Precondition (the trap): a preset uploaded via /preset/upload alone
has no Lua runtime attached. Calling /lua on it is a silent no-op
(globals controls, info, etc. are nil, errors go only to the logger).
You must first upload a Lua script to the same slot:
/electra1/preset/arm_upload <bank> <slot>
/electra1/lua_script/upload <lua_source> # opcode 0x01 0x0C
/electra1/preset/switch <bank> <slot> # force a fresh load so the runtime starts
After that, /lua starts ACKing and its side effects become visible.
API surface validated on hardware (2026-04-18, MK2 fw 4.1.4):
| Lua expression | Effect | Status |
|---|---|---|
controls.get(id):setName('NewLabel') |
Renames label | ✅ works |
controls.get(id):setColor(0xRRGGBB) |
Changes color — must be an integer literal, not a string | ✅ works |
controls.get(id):setColor('white') / 'orange' |
String argument | ❌ silent no-op |
controls.get(id):setVisible(bool) |
(extrapolated from /control/update; not individually re-tested under /lua) | likely ✅ |
info.setText(s), window.setInfoText(s), preset.setInfoText(s) |
Change header text | ❌ no visible effect on any variant tried |
controls.add(...) / controls.create(...) |
Create a new control at runtime | ❌ no such API — firmware cannot instantiate new control objects post-upload |
function definitions + later /lua "myfn()" |
Persisted across /lua calls within the same runtime | ✅ works |
preset.onReady = function() ... end |
Callback fires on preset (re)load | ⚠️ unverified — /preset/reload NACKed in testing; other reload paths untried |
Mutations made via /lua persist across preset switch-away-and-back,
same as /control/update.
7.3 Strategic note for "live-dialogue" clients (Kanopi pattern)
To give a client full live-mutation power without preset reuploads:
- At session start, upload the preset JSON and an accompanying Lua
script that exposes the mutation functions you'll want to call (thin
wrappers around
controls.get():setX()). - For subsequent live changes, send
/lua "yourFn(args)"— zero upload cost, <10 ms round-trip, persistent across slot switches. - You cannot create new controls live. If the session's control set changes, you must re-upload the preset (the 200 ms reconfig hit).
The thinnest possible mutation script — enough to unlock Kanopi-style live dialogue — is ~1 KB of Lua.
7b. Schema gotcha — tiles vs controls
If you're generating preset JSON from a tool that uses the web-editor's
internal "tiles" schema (the format app.electra.one saves into Firestore and
that the electraone-widgets repo
uses), you must convert it before uploading via SysEx — the firmware does not
parse it.
Symptom: /preset/upload ACKs at the transport level, the device fires
7E 05 preset-list-change and 7E 02 preset-switch events as if everything
worked, but the screen shows "no name - page 1" or stays empty, and
/preset/get afterwards returns 0 bytes.
| Schema | Top-level keys | Where it lives |
|---|---|---|
tiles (web-editor internal) |
schemaVersion, id, name, targetDevice, lua, devices, tiles[], pages, categories, firstPageId |
app.electra.one Firestore + the electraone-widgets repo + osc-bridge .cache/electra-import/ |
controls (device firmware) |
version, name, projectId, pages, devices, overlays, groups, controls[] |
The official Preset format spec — what /preset/upload must send. |
The web editor converts tiles → controls in JS (projectToPreset function,
offset ~127000–131000 in bundle 0c61af0.js) before calling its WebMIDI
output.send(). If your osc-bridge client is generating presets from
scratch following the controls schema described in §2, you're fine. If you're
pulling JSON from Firestore or from the electraone-widgets repo, run it
through the converter first.
A Python port of projectToPreset (byte-identical to the web editor, verified
against a live MIDI sniff) lives in the
electra-one-mcp plugin at
server/preset_converter.py. Translate to Rust as needed.
The same plugin also ports presetToProject (the reverse direction) so you
can pull a preset off the device and write it back in tiles form for
git diff-style workflows.
7c. File Transfer API (for very large files / multi-file deploys)
In addition to the simple uploads in §2 (01 01 Upload Preset, 01 0C Upload Lua, 01 0F devices, 01 12 data, 01 11 performance), the device exposes
a transactional file-transfer API for large or multi-file deploys:
| Step | SysEx | Purpose |
|---|---|---|
| 1 | F0 00 21 45 01 2D F7 |
Open cache (begin transaction) |
| 2 | F0 00 21 45 01 2E <fileId> <s0> <s1> <s2> <s3> F7 |
Register a file + its size (4×7-bit LE) |
| 3 | F0 00 21 45 01 2F <fileId> <data> F7 |
Send chunk (one SysEx per chunk; data must stay 7-bit) |
| 4 | F0 00 21 45 04 2D <commit-json> F7 |
Commit + verify MD5 + move to final location |
type: values supported: firmware, bootloader, preset, lua,
luaModule, ui, config, deviceList, datafile, performance.
location: values: slots, updates, assets, modules, presets, root.
Known limitation on firmware 4.1.4: commit silently rolls back when
type:"preset" is in the commit JSON. The web editor never uses FT for
presets (only for firmware, luaModule, multi-file slots deploys with
Lua + Devices + Performance + Persisted at once). Stick with the simple
01 01 + 01 0C path for preset+lua and reserve FT for luaModule
uploads (the only way to write to /ctrlv2/lua/<namespace>/<file>.lua
without a host filesystem mount).
Reference: filetransfer.html + forum #592 (staff posts #9, #16 on chunk sizes and reliability).
8. Hardware constraints
- Max preset size: ~100 KB of JSON. Larger layouts must be split.
- Reconfiguration latency: ~200 ms between
/preset/uploadand the device being ready to report touches on the new layout. Not suitable for real-time morphing; fine for scene/section changes. - Storage: 6 banks × 12 slots = 72 persistent preset slots in flash.
- USB ports: the MK2 exposes 3 virtual MIDI ports. Port 1 ("Electra
Controller") is the main one for both SysEx config AND control CC traffic
— use this for osc-bridge. Port 2 is a MIDI passthrough for connected gear.
Port 3 ("MIDIIN3/MIDIOUT3" on Windows, "CTRL" in Electra docs) is the
Management Port and accepts SysEx only — CC messages sent here arrive at the
device (USB LED blinks) but don't update on-screen values. Bottom line for
osc-bridge: use Port 1 (
--out-port <main_idx> --in-port <main_idx>). - Touch-sensitive pots (12): report
/pot/touchfor begin/end contact events. Useful for "pick up" behavior to avoid value jumps when a knob is first touched.
9. Known limitations of the current driver
- Only
cc7messages produce semantic routes. Extend the/preset/uploadscript inelectra-one.jsonto handlecc14/nrpn/program/sysex. /preset/arm_uploadis historically named after an operation it is not (it is actually Electra's "Set Preset Slot"). Renaming would break existing users; keep the name unless a major version bump is planned.- Ack/Nack replies are surfaced as OSC events, but the bridge does not yet
correlate them to the original upload request — client-side tracking of
tx_lsb/tx_msbis currently the caller's responsibility. - Upload does not auto-switch the UI to preset view. Firmware 4.1.4
verified behaviour: after
/preset/upload, the preset is loaded into the selected slot (confirmed via/preset_list/get) AND becomes the active preset for MIDI routing (/preset/switchedevent fires), BUT if the device was on the Menu / Home screen at upload time it stays there. The user must press the device's Home/Preset physical button to exit the menu and see the preset's controls. No documented SysEx command forces a UI screen change. - Midir / Windows truncates SysEx replies at 1024 bytes.
/preset/geton a preset larger than ~1KB returns a partial SysEx withoutF7terminator. The device's side is fine — it's the host-side MIDI driver buffer. Workarounds: fetch presets over USB mass-storage if the device supports it, or use Electra Console to export. (A possible osc-bridge fix: accumulate partial SysEx across multiple midir callbacks.)
10. For LLM-driven integrators
When writing new client code against this device:
- Read this file first (
/bridge/docsreturns it). - Always call
/electra1/routes/listafter upload — do not derive addresses. - Assume value range is always normalized 0..1 on the OSC wire.
- Treat
/electra1/ackand/electra1/nackas upload outcome signals. - When generating a preset JSON, prefer existing template-mutation over building from scratch — the format has many cross-references (pageId, deviceId) that are easy to get subtly wrong.
- If you have a
tiles-schema JSON (web editor's internal format), convert tocontrolsschema BEFORE upload (see §7b). The firmware silently rejects tiles JSON.
11. Layout math reference (MK2)
Extracted from app.electra.one's bundle 0c61af0.js (offsets ~129500
defaults + ~159200 slot helpers + ~134272 reverse math). Verified against a
live MIDI sniff: slotId=1, span=1, vspan=0 → bounds=[181, 6, 158, 16],
potId=8, byte-identical to web editor output.
Constants
mk2: numPages=12, slotsPerPage=72, slotsPerRow=6, rowsOnPage=6
slotsInSection=24, controlsInSection=12
displayWidth=1024, displayHeight=565
controlWidth=168, controlHeight=60
groupWidth=168, groupHeight=30, groupSpanHeight=97
maxVspan=6
rowY=[0, 30, 90, 120, 180, 210, 270, 300, 360, 390, 450, 480]
The 6×12 grid alternates rows: even-y rows (y=0,2,4,…) are label/group rows (h=30); odd-y rows are control rows (h=60). A "section" is one label + one control row pair; the device has 6 sections per page.
Forward (slotId → bounds + pot)
def slot_to_bounds(slot, span=1, vspan=0):
x = slot % 6
y = (slot // 6) % 12
if y % 2 == 0: # label/group row
w = 146 * span + 21 * (span - 1) + 12
h = (90 * vspan - 9) if vspan > 0 else 16
px = 20 + 167 * x - 6
else: # control row
w, h = 146, 56
px = 20 + 167 * x
py = 6 + 22 * ((y // 2) + (y % 2)) + 68 * (y // 2)
return [px, py, w, h]
def slot_to_pot(slot):
x = slot % 6
return x + 1 if (slot // 6) % 4 == 1 else x + 7
def slot_to_page_id(slot): return slot // 72 + 1
def slot_to_set(slot): return ((slot // 6) % 12) // 4 + 1
Reverse (bounds → slotId)
def bounds_to_slot(bounds, page_id=1):
col = bounds[0] // 170
row_section = (bounds[1] - 6) // 90
row_offset = 0 if (bounds[1] - 6) % 90 == 0 else 1
return 72 * (page_id - 1) + 6 * (2 * row_section + row_offset) + col
For the Mini variant (4 cols × 6 rows, 24 slots/page, different constants) see
the bundle around offset 157783, or the matching _MiniLayout class in the
electra-one-mcp plugin.
12. Note on USB port routing
§8 recommends Port 1 (Electra Controller) as the osc-bridge target for both
SysEx config AND CC traffic. This holds for osc-bridge's mixed
config-plus-runtime workflow, but for SysEx-only admin work (preset upload,
file transfer, event subscription, executing Lua, querying state), the CTRL
port is the conventional target:
- Port 1 —
Electra Controller(no suffix). Carries CC/Note traffic to/from the active preset's MIDI device assignments. The bundle routesapp.electra.one's default MIDI here. Per-channel routing applies. - Port 2 —
MIDIOUT2 / MIDIIN2. Same as Port 1 but for the second MIDI cable; pass-through to externally-connected gear via the device's MIDI passthrough. - Port 3 (CTRL) —
MIDIOUT3 / MIDIIN3. Admin / SysEx / events. Theapp.electra.onebundle's auto-selection regex prefers names matching/Electra.*(CTRL|Port 3|MIDI 3)/i. Every documented SysEx admin command in §2 + §6 + §7 works here. All7E XXunsolicited events come out of this port. CC sent here may light the device's USB LED but does not route to controls.
Practical guidance:
- osc-bridge default: Port 1 (the existing recommendation). Carries both CC and SysEx; the device's command interpreter accepts most SysEx admin on any port.
- Pure SysEx admin / scripting clients (preset push, Lua REPL, snapshot management, file transfer): Port 3 (CTRL) is the conventional target — guarantees no collision with active-preset CC traffic.
13. Cross-reference: complete SysEx catalog
For the full 62-command SysEx vocabulary (every host→device command + every
7E XX / 7F XX event), see:
electra-one.jsonin this folder — what osc-bridge wraps as OSC routes- The electra-one-mcp plugin's
docs/structured/sysex_commands.json— same catalog with payload-shape metadata, queryable via itsget_sysex_commandMCP tool - Official protocol doc
Communities
Where Electra One MK2 owners meet, share and help each other:
- Electra One forum, forum
Share and load its sounds
Plug the Electra One MK2 into your computer, open shared presets in Chrome, Edge or Opera and press Connect my synth: SyntHub finds it, takes the sound it plays and names it. Sounds others shared for it load from their page the same way.
https://docs.electra.one/developers/midiimplementation.html · licence not stated
MIDI controls
33 controls, from the source at firmware 4.x
SysEx commands
| Command | Arguments | Name to send |
|---|---|---|
| Info get | /electra1/info/get | |
| Runtime get | /electra1/runtime/get | |
| Config get | /electra1/config/get | |
| Preset list get | /electra1/preset_list/get | |
| Usb host get | /electra1/usb_host/get | |
| Preset get | bank: u7, slot: u7 | /electra1/preset/get |
| Preset slot get | bank: u7, slot: u7 | /electra1/preset_slot/get |
| Lua script get | bank: u7, slot: u7 | /electra1/lua_script/get |
| Device overrides get | bank: u7, slot: u7 | /electra1/device_overrides/get |
| Persisted get | bank: u7, slot: u7 | /electra1/persisted/get |
| Performance get | bank: u7, slot: u7 | /electra1/performance/get |
| Preset switch | bank: u7, slot: u7 | /electra1/preset/switch |
| Preset arm upload | bank: u7, slot: u7 | /electra1/preset/arm_upload |
| Preset reload | /electra1/preset/reload | |
| Page switch | page: u7 | /electra1/page/switch |
| Control set switch | set: u7 | /electra1/control_set/switch |
| Bottom bar text | text: string | /electra1/bottom_bar/text |
| Value text | control_id: u14, value_id: u7, text: string | /electra1/value_text |
| Control update | control_id: u14, json: string | /electra1/control/update |
| Events port | port: u7 | /electra1/events/port |
| Events subscribe | flags: u7 | /electra1/events/subscribe |
| Logger enable | status: bool | /electra1/logger/enable |
| Logger port | port: u7 | /electra1/logger/port |
| Repaints | cmd: u7 | /electra1/repaints |
| Debug | status: bool | /electra1/debug |
| Midi learn | status: bool | /electra1/midi_learn |
| Reboot | /electra1/reboot | |
| Lua | text: string | /electra1/lua |
| Lua script upload | text: string | /electra1/lua_script/upload |
| Preset remove | bank: u7, slot: u7 | /electra1/preset/remove |
| Preset clear slot | bank: u7, slot: u7 | /electra1/preset/clear_slot |
| Lua script remove | bank: u7, slot: u7 | /electra1/lua_script/remove |
| Config remove | /electra1/config/remove |
Use it
Find the MIDI ports, then start the bridge with this driver:
osc-bridge detect # prints the ready-to-run line for what is plugged in
osc-bridge run --device electra-one/electra-one --out-port <N> --in-port <M>
Then send OSC to 127.0.0.1:7777, for example:
osc-bridge osc-send /electra1/info/get
From Claude or any MCP client, the osc-bridge mcp server exposes this driver as electra1: ask “what can the Electra One MK2 do?” and it reads this map with list_routes. See the MCP guide.
How it is recognised
- The Electra One MK2 answers the maker's request
F0 00 21 45 02 7F F7withF0 00 21 45 01 7F …. - Its firmware version is in byte 6 of the answer (the text of one key of a JSON answer).