SyntHub
Data updated 2026-10-22JSONCSVMIDNAMOSCQuery

Nonlinear Labs C15

The Nonlinear Labs C15 MIDI implementation: 8 settings: 8 with a MIDI CC, each named, for Claude (MCP), SuperCollider or any OSC app.

    Maker
    Nonlinear Labs
    Source
    MIDI Guide · Repository
    Licence
    CC-BY-SA-4.0 MIDI Guide (https://midi.guide) by Pencil Research and contributors

    MIDI controls

    8 settings: 8 with a MIDI CC, from the source at per pencilresearch canonical CSV

    Pedals

    ControlCCRangeName to send
    Pedal 120 / 520–16383/c15/pedals/pedal_1
    Pedal 221 / 530–16383/c15/pedals/pedal_2
    Pedal 322 / 540–16383/c15/pedals/pedal_3
    Pedal 423 / 550–16383/c15/pedals/pedal_4

    Ribbons

    ControlCCRangeName to send
    Ribbon 124 / 560–16383/c15/ribbons/ribbon_1
    Ribbon 225 / 570–16383/c15/ribbons/ribbon_2

    Expression

    ControlCCRangeName to send
    Aftertouch26 / 580–16383/c15/expression/aftertouch

    Velocity

    ControlCCRangeName to send
    High resolution velocity lsb880–127/c15/velocity/high_resolution_velocity_lsb

    Performance MIDI

    Notes, pitch bend and any CC are also available: /c15/note/on <note> <velocity>, /c15/cc/<number> <value>, /c15/pitchbend <0-16383>, /c15/program_change <n>.

    JSON

    Use it

    Find the MIDI ports, then start the bridge with this driver:

    osc-bridge detect        # prints the ready-to-run line for what is plugged in
    osc-bridge run --device nonlinear-labs/c15 --out-port <N> --in-port <M>

    Then send OSC to 127.0.0.1:7777, for example:

    osc-bridge osc-send /c15/pedals/pedal_1 8191

    From Claude or any MCP client, the osc-bridge mcp server exposes this driver as c15: ask “what can the Nonlinear Labs C15 do?” and it reads this map with list_routes. See the MCP guide.

    Limitations

    CC/NRPN only. SysEx (preset management, display control, bulk dump/load, vendor-proprietary opcodes) is NOT covered by pencilresearch. To extend this device with SysEx, sniff the vendor editor, add `sysex.header/footer` + `commands` blocks, and use `update_device.md` PR template.

    Other sources of this version

    Other sources describe the Nonlinear Labs C15 at this firmware; each keeps its credit.

    Frequently asked questions

    How many parameters of the Nonlinear Labs C15 can be controlled over MIDI?

    SyntHub's map of the Nonlinear Labs C15 lists these parameters: 8 with a MIDI CC, each with a readable name. The full chart is on this page.

    Can an AI agent like Claude control the Nonlinear Labs C15?

    Yes: SyntHub's hosted MCP server knows the 8 settings of the Nonlinear Labs C15, and its browser relay lets the agent send them to it.